A-2INSTALLATION INSTRUCTIONSAPPENDIX B(852-6-4190-574-00-1)CS-KS12NB41 & CZ-18BT1U + CU-KS12NK1ACS-KS18NB4UW & CZ-18BT1U + CU-KS18NKUCS-KS18NB
9(1) Recommended dimensions of the baffle platesDFECJHLIBKQRAGO(3- 6.5 mm)3- 1/4"(2- 6 mm)2- 15/64"ABHCEFKIJGGD(4- 6.5 mm)4- 1
10(3) Installation procedurePanel frontPanel side RPanel side LFig. 5hFig. 5i2. Air Discharge Baffle1. Remove the panels front, side L and R from the
11Panel topPanel frontPanel side RPanel side LFig. 5k1. Air Intake Baffle(1) Left side1. Remove the top panel from the unit.2. Remove the panel side L
12Hole-in-anchorConcrete InsertSuspension bolt (M10 or 3/8")Hole-in-plug(locally purchased)Fig. 6-123-5/8"(600mm)21-1/32"(534mm)Ceiling
13 In cases where it is necessary to raise the height of thedrain piping, the drain piping can be raised to a maximumheight of 2.78 ft. (850 mm) abov
14Amust be within the range of 1/2"(13mm) to 23/32"(18mm). (Fig. 6-11)If not within this range, malfunction or other trouble may occur.Ceili
15(2) Removing the corner cover andindicator covera) While lightly pressing the cen-ter of the corner cover, pull upthe tab for the screw hole.Use the
16Fig. 6-23Fig. 6-24 Fig. 6-25fit into the holes in the ceiling panel.Place the corner cover so that the 3 tabsThen fasten it in place with the suppli
3-7. Wiring InstructionsGeneral precautions on wiring(1) Before wiring, confirm the rated voltage of the unit as shown on its nameplate,then carry ou
18Cross-Sectional (A)+(B) (A) Power Supply Wiring Length (ft) (C) ControlFuse or Circuit Area (AWG)(B) Power Line Length (ft) Line Length (ft)Model (#
This air conditioner uses the refrigerant R410A.External diameter of service port R410A: 5/16"Split System Air Conditioner85264190574001 2011INST
19When connecting each power wire to the corresponding terminal, fol-low the instructions “How to connect wiring to the terminal” and fastenthe wire s
20 For stranded wiring(1) Cut the wire end with a cutting pliers, then strip the insulation to expose the stranded wiring about 3/8" (10 mm) and
215. Refrigerant Tubing5-1. Use of the Flaring MethodMany of the conventional split system air conditionersemploy the flaring method to connect refr
225-4. Connecting Tubing between Indoor and Outdoor Unitsa) Tightly connect the indoor side refrigerant tubing exten-ded from the wall with the outdoo
23Insulated tubesDrain hoseClampHiLoIndoor unitOutdoor unitManifold valve(Exclusively for R410A)PressuregaugeVacuum pumpCharging hose(Exclusively for
24(4) With the “Lo” knob of the manifold valve open, runthe vacuum pump. The operation time for the vacu-um pump varies with tubing length and the cap
25How to Test Run the Air ConditionerAfter turning on the power of the air conditioner, use theremote controller and follow the steps below to conduct
26 Pump DownPump down means collecting all refrigerant gas in thesystem back into the outdoor unit without losing any ofthe gas. Pump down is used wh
277. Remote Controller Installation PositionThe remote controller can be operated from either anon-fixed position or a wall-mounted position.To ensur
28ACL(Reset)button1HR.TIMERbuttonON/OFFoperationbuttonHIGH POWERbutton8. Address Switch8-1. Address Setting of the Remote ControllerThe address can
2IMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operatingstandards. As the installer or service person, it
Operating InstructionsCZ-RD515U(852-6-4181-230-00-1)APPENDIX CA-3
Wired Remote ControllerModel No.CZ-RD515UOperating InstructionsPanasonic Corporation1006 Kadoma, Kadoma City, Osaka, Japan85264181230001 CV6233187877T
2FEATURES• Microprocessor Controlled OperationThe interior compartment of the remote controller contains several features to facilitate automatic oper
3INSTALLATION LOCATIONWe recommend that this wired remote controller be installed properly by qualified installation technicians in accordance with th
4REMOTE CONTROLLERDisplayInformation on the operating conditions is displayed while the remote controller is switched on. If the unit is turned off, o
5SensorA temperature sensor inside the remote controller senses the room temperature.ON/OFF operation buttonThis button is for turning the air conditi
6REMOTE CONTROLLER (DISPLAY)(1) Operation modeAUTO ...(only for COOL/DRY/HEAT Model)HEAT ...
7OPERATION WITH THE REMOTE CONTROLLER1. Automatic Operation(only for COOL/DRY/HEAT Model)• Single useThis unit automatically switches between cooling
83. Adjusting the Fan SpeedA. Automatic fan speedSimply set the FAN SPEED selector button to the position.This automatically sets the best fan spee
3 8VHWKHIODUHPHWKRGIRUFRQQHFWLQJWXELQJ $SSO\UHIULJHUDQWOXEULFDQWWRWKHPDWFKLQJVXUIDFHVRIthe flare and union tubes before connecting the
9SETTING THE TIMER1. How to set the present time(Example) To set to 9:10 pm.2. How to set the OFF time(Example) To stop the air conditioner at 11:30
10USING THE 1-HOUR OFF TIMER1. 1-Hour OFF TimerThis function causes the unit to operate for one hour and then stop, regardless of whether the unit is
A-4INSTALLATION INSTRUCTIONSCZ-RD515U(852-6-4190-592-00-0)APPENDIX D
Parts supplied with the remote controllerSee Table 1.Remote controller installation guidelines Mount the remote controller 3.3 to 4.9 ft. (1 to 1.5me
2A. Installing with in-wall junction box(1) Install the junction box (locally purchased) into the wall.(Figs. 2-a and 3)(2) Pass the wire harness thro
Fig. 8IndicatorWire harnessCeilingpanelTerminal coverClamps7P IND and 4P RCwiring connector5P FLAPwiring connectorClamping strapFLAPRCIND7P4P5P FLAPwi
4Fig. 9Fig. 10Fig. 11ON/OFFoperation button1 HR.TIMERbuttonNIGHT SETBACKbuttonACL (Reset)buttonSENSOR buttonOPERATION lampTIMER lampHIGH POWER lampREM
DC1111-0
4Printed on container boxFor unit & PVCtube connectionFor drain hoseconnectionRemarksQ’tyFor full-scaleinstallationdiagram12444421For temporarilys
51-5. Additional Materials Required for Installation1. Refrigeration (armored) tape2. Insulated staples or clamps for connecting wire(See local codes
62-2. Outdoor UnitAVOID: heat sources, exhaust fans, etc. (Fig. 3) damp, humid or uneven locations.DO: choose a place as cool as possible. choose
72-3. Baffle Plate for the Outdoor Unit(Low Ambient Cooling models only)It is recommended to use baffle plates for models CU-KS12NK1A and CU-KS18NKUA
8(1) Recommended dimensions of the baffle platesDECJHKGBIPQAFN(2- 6.5 mm) 2- 1/4"(2- 6 mm) 2- 15/64"ABHCEFGGMLKIJD(4- 6.5 mm)